C 00005800 C*********************************************************************** C COPYRIGHT ATLANTIC RICHFIELD COMPANY 1991 * C*********************************************************************** C====================================================================== 00005900 C 00006000 CU PROCESS GDPI -- CALIBRATED SPECTRAL ANALYSIS 00006100 CU DATA CARD (1) -- DEFINES F, S OR D RANGE AND PLOT TYPE 00006200 CU 00006300 CU NO. OF CARDS: REQUIRED = 1 ALLOWED = 1 00006400 CU 00006500 CU REQ OR OPT 00006600 CU DF COLS DESCRIPTION OR DEFAULT 00006700 CU -- ----- ----------- -----------00006800 CU 1 1- 4 'GDPI' | REQ |00006900 CU 2 - 5 PROCESS NUMBER | 0 |00007000 CU 3 - 6 NOT USED | |00007100 CU 4 - 7 PROCESSING MODE |LINE CARD|00007200 CU 'S' = SHOT POINT MODE | |00007300 CU 'D' = DEPTH POINT MODE | |00007400 CU 'F' = FILE MODE | |00007500 CU 5 8-10 FOR PROGRAMMING USE | |00007600 CU 6 11-15 STARTING SHOTPOINT, DEPTH POINT, FILE NUMBER | REQ |00007700 CU 7 16-20 ENDING SHOTPOINT, DEPTH POINT, FILE NUMBER | DF6 |00007800 CU 8 21-25 NOT USED | |00007900 CU 9 26-35 TEN COLUMNS, FIELDS 9 AND 10 | NEXT NO.|00008000 CU 10 DATA SET IDENTIFICATION | |00008100 CU NORMALLY BLANK--SYSTEM ASSIGNS NEXT NUMBER | |00008200 CU 11 36-40 DATA SET TYPE | T |00008300 CU 'T' = TAPE WITH IBM STANDARD LABEL | |00008400 CU 'N' = TAPE WITHOUT IBM STANDARD LABEL | |00008600 CU 12 41-45 TAPE RECORDING DENSITY (NOT USED FOR DISK) | H FOR T |00008700 CU 'L' = 800 BPI, 'M' = 1600 BPI, 'H' = 6250 BPI | L FOR N |00008800 CU 13 46-50 NOT USED | |00008900 CU 14 51-55 FOR OPERATIONS USE. | |00009100 CU 15 56-60 NOT USED | |00009200 CU 16 61-65 NOT USED | |00009300 CU 17 66-70 NOT USED | |00009400 CU 18 71-75 NOT USED | |00009500 CU 19 76-80 'ESP' = NO DISPLAY | ESP |00009600 CU 'OFESP' = OFFLINE VARIAN DISPLAY | |00009700 CU -----------00010000 CU DF NOTES 00010100 CU -- ----- 00010200 CU 00011000 CU 1 ONLY ONE PROCESS OCCURRENCE IS ALLOWED PER JOB. 00011000 CU 00011000 CU 19 OUTPUT IS IN VECTOR FORMAT. 'OFESP' IMPLIES THAT THE OUTPUT 00011100 CU WILL BE PLOTTED OFFLINE USING THE ELECTROSTATIC PAPER PLOTTER. 00011200 CU 'ONESP' IS NOT SUPPORTED BY THIS PROCESS. 00011200 CU 00011700 CU EJECT 00011800 CU DATA CARD (2) -- DEFINES PROCESSING PARAMETERS 00011900 CU 00012000 CU NO. OF CARDS: REQUIRED = 1 ALLOWED = 1 00012100 CU 00012200 CU REQ OR OPT 00012300 CU DF COLS DESCRIPTION OR DEFAULT 00012400 CU -- ----- ----------- -----------00012500 CU 1 1- 4 'GDPI' | REQ |00012600 CU 2 - 5 PROCESS NUMBER | 0 |00012700 CU 3 - 6 NOT USED | |00012800 CU 4 - 7 NOT USED | |00012900 CU 5 8-10 'CL2' | REQ |00013000 CU 6 11-15 START TIME FOR ANALYSIS (MS) | REQ |00013100 CU 7 16-20 END TIME FOR ANALYSIS (MS) | REQ |00013200 CU 8 21-25 LINE PRINTER OPTIONS | 0 |00013300 CU '0' SUPPRESSES ALL DUMPS | |00013310 CU '1' LISTS AMPLITUDE AND PHASE VALUES | |00013320 CU '2' LISTS INVERSE TRANSFORM | |00013330 CU '3' EQUIVALENT TO BOTH '1' AND '2' | |00013340 CU 9 26-30 PHASE SPECTRUM PLOT OPTION | 0 |00013400 CU '0' SUPPRESSES PLOT | |00013500 CU '1' PRODUCES PHASE PLOT | |00013600 CU 10 31-40 0-DB OR REFERENCE SPECTRAL AMPLITUDE |NOTE DF10|00013800 CU 12 41-45 NUMBER OF TRAILING ZEROS TO AUGMENT WINDOW | 0 |00014300 CU 13 46-50 TOTAL TRACES TO PLOT IN A GATHER | REQ |00014400 CU 14 51-60 UNITS TO WHICH CALIBRATION IS MADE | OPT |00014600 CU 16 61-70 UNITS OF 0-DB LEVEL SPECIFIED IN DF 10 | OPT |00014700 CU 18 71-75 GRID LINE SUPPRESSOR OPTION | 0 |00014800 CU '0' = PLOT GRID LINES ON SPECTRAL PLOTS | |00014900 CU '1' = OMIT GRID LINES ON SPECTRAL PLOTS | |00015000 CU 19 76-80 DATA EDITING OPTIONS | 0 |00015200 CU '0' = CIRCULAR TIME SHIFT FOR PHASE UNWRAP | |00015300 CU '1' = DC COMPONENT REMOVAL | |00015310 CU '2' = WINDOW TAPER APPLICATION | |00015320 CU -----------00015400 CU 00015500 CU DF NOTES 00015600 CU -- ----- 00015700 CU 00016000 CU 10 THIS IS THE 0-DB LEVEL TO WHICH THE AMPLITUDE SPECTRUM WILL BE 00016010 CU REFERRED. FLOATING POINT VALUE IS PERMISSIBLE. DEFAULT=1.0 . 00015710 CU 00015710 CU 13 MUST CORRESPOND EXACTLY TO THE NUMBER OF CHANNEL NO-CALIBRATION- 00015800 CU DISTANCE TRIPLETS ON CARD(S) 4. 00015900 CU 00016000 CU 14 MUST BE LEFT-JUSTIFIED IF GIVEN. 00016010 CU 00016000 CU 16 MUST BE LEFT-JUSTIFIED IF GIVEN. 00016010 CU 00016000 CU 19 ADD INDICATORS TO INVOKE MORE THAN ONE OPTION. 00016010 CU 00016100 CU EJECT 00017100 CU 00017110 CU DATA CARD (3) -- DEFINES ADDITIONAL PROCESSING PARAMETERS 00017200 CU 00017300 CU NO. OF CARDS: REQUIRED = 1 ALLOWED = 1 00017400 CU 00017500 CU REQ OR OPT 00017600 CU DF COLS DESCRIPTION OR DEFAULT 00017700 CU -- ----- ----------- -----------00017800 CU 1 1- 4 'GDPI' | REQ |00017900 CU 2 - 5 PROCESS NUMBER | 0 |00018000 CU 3 - 6 NOT USED | |00018100 CU 4 - 7 NOT USED | |00018200 CU 5 8-10 'CL3' | REQ |00018300 CU 6 11-15 START FREQUENCY TO PLOT (HZ) | 0 |00018400 CU 7 16-20 HIGHEST FREQUENCY TO PLOT (HZ) | NYQUIST |00018500 CU 8 21-25 VERTICAL/HORIZONTAL PLOTTING SCALE FACTOR | REQ |00018800 CU 9 26-30 SPECTRAL ENERGY DISCRETIZATION FOR PRINTING | 0 |00019300 CU '0' = DISCRETIZE AT EQUAL INCREMENTS OF DF10 | |00019310 CU '1' = DISCRETIZE AT OCTAVES OF DF10 | |00019320 CU 10 31-35 FREQUENCY TO USE WITH DF9 (HZ) | REQ |00019330 CU 36-80 NOT USED | |00019340 CU -----------00019400 CU 00019500 CU DF NOTES 00019600 CU -- ----- 00019700 CU 00019800 CU 5 FLOATING POINT VALUES ARE PERMISSIBLE FOR ALL FIELDS 00019800 CU ON THIS CARD EXCEPT DF9. 00019800 CU 00019800 CU 8 THE LENGTH OF THE X-AXIS WILL BE THIS FACTOR TIMES 8. 00019900 CU THE LENGTH OF THE Y-AXIS WILL BE THIS FACTOR TIMES 5. 00020000 CU 00020100 CU EJECT 00020200 CU DATA CARD (4) -- DEFINES TRACES TO BE PLOTTED 00023700 CU 00023800 CU NO. OF CARDS: REQUIRED = 1 ALLOWED = 100 TRACES 00023900 CU REQ OR OPT 00024000 CU DF COLS DEFINITION OR DEFAULT 00024100 CU -- ----- ---------- -----------00024200 CU 1 1- 4 'GDPI' | REQ |00024300 CU 2 - 5 PROCESS NUMBER | 0 |00024400 CU 3 - 6 NOT USED | |00024500 CU 4 - 7 NOT USED | |00024600 CU 5 8-10 'CL4' | REQ |00024700 CU 6 11-15 NOT USED | |00024800 CU 7 16-20 NOT USED | |00024800 CU 8 21-25 CHANNEL OR TRACE NUMBER (#1) | REQ |00024800 CU 9 26-35 CALIBRATION CONSTANT (#1) | REQ |00024900 CU 11 36-45 SOURCE-RECEIVER DISTANCE (#1) | REQ |00025000 CU 13 46-50 CHANNEL OR TRACE NUMBER (#2) | OPT |00025100 CU 14 51-60 CALIBRATION CONSTANT (#2) |NOTE DF9 |00025110 CU 16 61-70 SOURCE-RECEIVER DISTANCE (#2) |NOTE DF11|00025120 CU -----------00025200 CU 00025300 CU DF NOTES 00025400 CU -- ----- 00025500 CU 00025510 CU 8 ANY TRACE NOT APPEARING ON THESE CARDS WILL NOT BE PLOTTED. 00025600 CU 00025800 CU 9 FLOATING POINT VALUE IS PERMISSIBLE. 00025800 CU 00025800 CU 11 FLOATING POINT VALUE IS PERMISSIBLE. 00025800 CU 00025800 CU EJECT 00025800 CU DATA CARD (5) -- DEFINES LABEL 00020300 CU 00020400 CU NO. OF CARDS: REQUIRED = 0 ALLOWED = 1 00020500 CU 00020600 CU REQ OR OPT 00020700 CU DF COLS DESCRIPTION OR DEFAULT 00020800 CU -- ----- ----------- -----------00020900 CU 1 1- 4 'GDPI' | REQ |00021000 CU 2 - 5 PROCESS NUMBER | 0 |00021100 CU 3 - 6 NOT USED | |00021200 CU 4 - 7 NOT USED | |00021300 CU 5 8-10 'CL5' | REQ |00021400 CU 6 11-50 LABEL FIELD | OPT |00021500 CU 51-80 NOT USED | |00022300 CU -----------00022400 CU DF NOTES 00022500 CU -- ----- 00022600 CU 00022610 CU 6 THIS LABEL APPEARS ACROSS THE TOP OF THE PLOT. 00022700 CU 00023500 CU 00023600 CUEND 00025900